Triplex Pump Output per Stroke Calculator
Enter the declared drilling engineering inputs below to solve PO. Variable definitions, units, the default calculation, and the available source trail are included on this page.
What is available in this record
This record provides the functioning calculator, formula, declared variables and units, a reproducible default result, and the available citation metadata. A separately written engineering interpretation has not yet been published for this calculation.
Formula, variables, and default calculation
Reproducible default result
With the default values shown below, the calculation returns PO = 0.104976 bbl/stk. Defaults demonstrate the implementation; they are not recommended field values.
6
12
Input definitions
D_l
inLiner Diameter
L_s
inStroke Length
Output definitions
PO
Pump Output
D_l
Liner Diameter
L_s
Stroke Length
Source and record status
Source metadata identifies the relationship implemented by the calculator. Check the cited edition, unit basis, and scope against the engineering case before operational use.
Lapeyrouse, N.J. 2002. Formulas and Calculations for Drilling, Production and Workover, 2nd Edition, Page 7.
Open source reference