Closed-Ended Pipe Buoyed Weight with No Fluid Inside Calculator
Enter the declared drilling engineering inputs below to solve W_buoyed_closed. Variable definitions, units, the default calculation, and the available source trail are included on this page.
What is available in this record
This record provides the functioning calculator, formula, declared variables and units, a reproducible default result, and the available citation metadata. A separately written engineering interpretation has not yet been published for this calculation.
Formula, variables, and default calculation
Reproducible default result
With the default values shown below, the calculation returns W_buoyed_closed = 16.126276 lb/ft. Defaults demonstrate the implementation; they are not recommended field values.
19.5
2.875
10
Input definitions
W_air
lb/ftPipe Weight in Air
OD
inPipe Outside Diameter
FW
ppgExternal Fluid Weight
Output definitions
W_buoyed_closed
Buoyed Weight of Closed-Ended Pipe
W_air
Pipe Weight in Air
OD
Pipe Outside Diameter
FW
External Fluid Weight
Source and record status
Source metadata identifies the relationship implemented by the calculator. Check the cited edition, unit basis, and scope against the engineering case before operational use.
IADC WellSharp Formula Sheet, field units, well completion/workover formula sheet.
Open source reference