Casing Pressure After Subsea Start-Up Calculator
Enter the declared drilling engineering inputs below to solve P_start. Variable definitions, units, the default calculation, and the available source trail are included on this page.
What is available in this record
This record provides the functioning calculator, formula, declared variables and units, a reproducible default result, and the available citation metadata. A separately written engineering interpretation has not yet been published for this calculation.
Formula, variables, and default calculation
Reproducible default result
With the default values shown below, the calculation returns P_start = 650 psi. Defaults demonstrate the implementation; they are not recommended field values.
800
150
Input definitions
SICP
psiShut-In Casing Pressure
P_cl
psiChoke Line Friction Loss
Output definitions
P_start
Casing or Choke Pressure After Subsea Start-Up
SICP
Shut-In Casing Pressure
P_cl
Choke Line Friction Loss
Source and record status
Source metadata identifies the relationship implemented by the calculator. Check the cited edition, unit basis, and scope against the engineering case before operational use.
IADC WellSharp Formula Sheet, field units, casing or choke pressure after subsea start-up.
Open source reference