Beggs-Standing Oil Formation Volume Factor Below Bubble Point Calculator
Enter the declared phase behavior and thermodynamics inputs below to solve B_o. Variable definitions, units, the default calculation, and the available source trail are included on this page.
What is available in this record
This record provides the functioning calculator, formula, declared variables and units, a reproducible default result, and the available citation metadata. A separately written engineering interpretation has not yet been published for this calculation.
Formula, variables, and default calculation
Reproducible default result
With the default values shown below, the calculation returns B_o = 1.354779 RB/STB. Defaults demonstrate the implementation; they are not recommended field values.
600
0.8
0.85
180
Input definitions
R_s
SCF/STBSolution Gas-Oil Ratio
gamma_g
fractionGas Specific Gravity
gamma_o
fractionOil Specific Gravity
T
°FTemperature
Output definitions
B_o
Oil Formation Volume Factor
F_beggs_standing
Beggs-Standing Formation Volume Factor Correlating Parameter
R_s
Solution Gas-Oil Ratio
T
Temperature
Source and record status
Source metadata identifies the relationship implemented by the calculator. Check the cited edition, unit basis, and scope against the engineering case before operational use.
Craft, B.C., Hawkins, M. and Terry, R.E. 1991. Applied Petroleum Reservoir Engineering, 2nd Edition, Page 37.