Accumulator Bottles Required for BOP Function Volume Calculator
Enter the declared drilling engineering inputs below to solve N_bottles. Variable definitions, units, the default calculation, and the available source trail are included on this page.
What is available in this record
This record provides the functioning calculator, formula, declared variables and units, a reproducible default result, and the available citation metadata. A separately written engineering interpretation has not yet been published for this calculation.
Formula, variables, and default calculation
Reproducible default result
With the default values shown below, the calculation returns N_bottles = 11 count. Defaults demonstrate the implementation; they are not recommended field values.
55
5
Input definitions
V_required
galRequired Usable Fluid Volume for BOP Functions
V_usable_bottle
gal/bottleUsable Fluid Volume per Accumulator Bottle
Output definitions
N_bottles
Accumulator Bottles Required
Source and record status
Source metadata identifies the relationship implemented by the calculator. Check the cited edition, unit basis, and scope against the engineering case before operational use.
Drilling Manual BOP accumulator unit rig operations requirements; DrillingFormulas.com accumulator usable-volume calculation.
Open source reference