Hydrostatic Pressure Drop per Foot Pulling Wet Pipe Formula
Hydrostatic Pressure Drop per Foot Pulling Wet Pipe calculates hydrostatic pressure drop per foot pulling wet pipe for well control workflows in drilling engineering.
How engineers use this formula
Use this formula when the listed inputs (MW, C_dp, D_dp, C_ann) are known and the assumptions behind the cited well control relationship match the engineering case being checked.
Assumptions
- Input values are representative for the well, reservoir, fluid, or equipment case being evaluated.
- The declared units match the field-unit constants used in the formula.
- The cited formula applies to the selected petroleum engineering workflow.
Limitations
- The calculation does not replace a full engineering model or operating procedure.
- Accuracy depends on the source correlation, assumptions, input quality, and unit consistency.
Common mistakes
- Mixing unit systems without converting the inputs.
- Using default example values as field recommendations.
- Applying the formula outside the source assumptions.
Default example
Using the default inputs, dP_wet_ft equals 0.343893 psi/ft.
12
0.0178
0.007
0.045
Inputs
MW
ppgMud Weight
C_dp
bbl/ftDrill Pipe Capacity
D_dp
bbl/ftDrill Pipe Displacement
C_ann
bbl/ftAnnular Capacity
Outputs
dP_wet_ft
Hydrostatic Pressure Drop per Foot Pulling Wet Pipe
MW
Mud Weight
C_dp
Drill Pipe Capacity
D_dp
Drill Pipe Displacement
C_ann
Annular Capacity
Source and review
reviewedIADC WellSharp Formula Sheet, field units; Cudd Well Control Technical Data Book, trip calculations.
Source